SGS Buxton is a product safety laboratory in Buxton, Derbyshire, that incorporates Baseefa and tests equipment for use in potentially explosive atmospheres. It carries out ingress protection testing to IEC 60529 for dust and water, covering IP5X and IP6X dust and IPX1 to IPX8 water, with immersion to 100 metres. Environmental exposure tests include heat endurance at 95°C and 90% RH, dry heat to 250°C and cold endurance to -75°C under IEC 60079-0. The laboratory is UKAS-accredited to ISO 17025, lab number 2593. It serves automotive, industrial, medical device, radio equipment, electricity meter and consumer goods customers.
IP Dust (IP5X/IP6X)
IP Water (IPX1 to IPX9K)
Temperature (Hot/Cold)
Humidity/Damp Heat
3C Test
Silverstone, Northamptonshire
New
3C Test in Silverstone is an Applus+ Laboratories EMC and environmental test lab serving automotive, EV battery, aerospace and defence, and consumer and industrial electronics customers. Its environmental work covers high and low temperature, thermal shock, thermal cycling, humidity, salt spray, altitude, sine and random vibration, shock, drop and topple, and combined climatic and vibration testing. Standards include BS EN 60068, ISO 16750, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. It is UKAS-accredited to ISO 17025, lab number 1204. A 200 kN shaker can be combined with a large climatic chamber for EV battery pack testing.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Axis Test Laboratories
Durham, Durham
New
Axis Test Laboratories in Durham is a UKAS-accredited environmental test lab serving marine, defence, rail, automotive, aerospace, oil and gas, renewable energy and industrial customers. It carries out dry heat, cold, thermal shock, damp heat, cyclic salt spray, sine and random vibration, half-sine shock and package drop testing. Standards include BS EN 60068, MIL-STD-810, BS EN 60945, BS EN 61373, ISO 9227 and ASTM B117. The lab is accredited to ISO 17025, lab number 7670. Its largest climatic chamber measures 2.0 x 3.0 x 2.0 m, and its shakers take static loads of up to 1,000 kg.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Shock
Salt Spray/Salt Fog
Cranage EMC & Safety
Market Drayton, Shropshire
New
Cranage EMC & Safety in Market Drayton, Shropshire, runs environmental tests alongside EMC and product safety work. Its climatic chambers cover temperature, humidity and damp heat, temperature cycling, solar radiation and salt spray. Mechanical tests include random and swept sine vibration from 5 Hz to 2 kHz and shock up to 500 m/s². Ingress protection testing covers dust and water from IP1X to IPX9K, with a 50 m² indoor IPX9K area. Standards include IEC 60068 and IEC 60529. The lab is UKAS-accredited to ISO 17025, lab number 1833, and serves medical, rail and industrial equipment makers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Solar Radiation
Element Warwick
Warwick, Warwickshire
New
Element Warwick, in Warwick, is an environmental test laboratory running climatic, dynamic and ingress protection tests. Climatic work covers high and low temperature, humidity, thermal shock, altitude to 35 mbar, driving sand and dust, driving rain, icing and salt corrosion. Dynamic work covers sine and random vibration on a shaker with 160 kN peak thrust, vibration at high and low temperature, classical shock, bump, drop and topple, and acceleration. IP testing covers IP5X to IPX8. Standards include IEC 60068, MIL-STD-810, DEF STAN 00-35, IEC 61373 and IEC 60529. It is UKAS-accredited to ISO 17025, lab number 31737, and serves aerospace, defence, energy and industrial sectors.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Shock
Combined Climatic and Vibration
IL
Intertek Leatherhead
Leatherhead, Surrey
New
Intertek Leatherhead, in Leatherhead, Surrey, runs climatic, vibration, shock and ingress testing alongside EMC, safety and medical testing at one site. Climatic work covers dry heat to +180 C, cold to -75 C, thermal cycling, and cyclic and steady-state damp heat from 10% to 98% rh, to IEC 60068 and MIL-STD-810. Mechanical tests include sine vibration from 2 to 5,000 Hz and half-sine shock up to 5,000 g. Dust and water ingress tests run to IEC 60529, covering IP5X and IP6X dust and IPX1 to IPX8 water. The lab is UKAS-accredited to ISO 17025, lab number 0029, and serves electronics, medical, automotive, building, industrial and energy customers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Sine Vibration
Resonate Testing
Newry, County Down
New
Resonate Testing in Newry provides vibration, shock, climatic, ingress protection, battery and fire testing from a single facility. Tests include sine and random vibration with combined climatic conditioning, classical and pyroshock, drop, temperature, humidity, thermal shock, altitude to 100,000 ft, IP dust and water, salt spray, sand and dust, rain and fluid susceptibility. Main standards are IEC 60068, MIL-STD-810, RTCA DO-160, DEF STAN 00-35, ISO 16750 and IEC 60529. The lab is UKAS-accredited to ISO 17025, lab number 9373, and is an ISTA Certified Laboratory. Capacity includes a 70 kN shaker. It serves space, aerospace, defence, automotive, energy, medical and industrial customers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Industrial is among the industries served by 7 UK environmental test labs on ESS Directory. IEC 60068 and the IP code in IEC 60529 are the usual references for industrial equipment. Services on file include Temperature (Hot/Cold) (7), Humidity/Damp Heat (7), Sine Vibration (6) and Mechanical Shock (6). The most common certifications are ISO 17025 (7), ISO 9001 (2) and Cyber Essentials (2).