Impact Solutions in Livingston, West Lothian, is a plastics and materials test laboratory offering accelerated weathering and light fastness testing. Its weathering lab runs Q-Sun xenon arc chambers with spray and QUV fluorescent UV testers, to standards including ISO 4892, ISO 16474, SAE J2527 and MIL-STD-810, under a UKAS flexible scope. It also tests UN dangerous goods packaging, including drop and stack tests. The lab is UKAS-accredited to ISO 17025, lab number 0402. Weathering work covers automotive materials, aerospace materials, paints and coatings, textiles, plastics and rubbers, adhesives and military applications.
UV Ageing/Weathering
Package Drop and Compression
Smithers - Leatherhead
Leatherhead, Surrey
FeaturedNew
Smithers Leatherhead runs a distribution testing laboratory in Leatherhead, Surrey, for pre-shipment testing of packaged products and environmental durability testing of unpackaged products and components. Tests include sine, random and mixed-mode vibration, classical shock, bump, drop, compression, thermal shock, high and low temperature, humidity and reduced-pressure altitude testing. Main standards are ISTA, ASTM D4169, IEC 60068, DEF STAN 00-35 and MIL-STD-810. The laboratory is ISTA Certified and UKAS-accredited to ISO 17025, lab number 0112. Facilities include walk-in climatic chambers and conditioning rooms from -50°C to +70°C. Sectors served include medical, electronics, automotive, aerospace and defence.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Shock
Sine Vibration
Axis Test Laboratories
Durham, Durham
New
Axis Test Laboratories in Durham is a UKAS-accredited environmental test lab serving marine, defence, rail, automotive, aerospace, oil and gas, renewable energy and industrial customers. It carries out dry heat, cold, thermal shock, damp heat, cyclic salt spray, sine and random vibration, half-sine shock and package drop testing. Standards include BS EN 60068, MIL-STD-810, BS EN 60945, BS EN 61373, ISO 9227 and ASTM B117. The lab is accredited to ISO 17025, lab number 7670. Its largest climatic chamber measures 2.0 x 3.0 x 2.0 m, and its shakers take static loads of up to 1,000 kg.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Shock
Salt Spray/Salt Fog
Medical Engineering Technologies (MET)
Dover, Kent
New
Medical Engineering Technologies (MET) in Dover, Kent, tests medical devices and their packaging, including transit simulation for shipping validation. Its UKAS ISO 17025 scope, lab number 7848, covers distribution testing to ASTM D4169 and ASTM D7386, random vibration of shipping containers, sinusoidal vibration to BS EN 60068-2-6, drop, impact and compression tests, and temperature and humidity conditioning of packages from -30°C to +60°C. Its vibration system takes payloads of up to 300 kg. The lab also carries out accelerated ageing and seal integrity testing for ISO 11607 packaging validation. It works with medical device and pharmaceutical packaging customers.
Transport Simulation
Package Drop and Compression
Sine Vibration
Random Vibration
Resonate Testing
Newry, County Down
New
Resonate Testing in Newry provides vibration, shock, climatic, ingress protection, battery and fire testing from a single facility. Tests include sine and random vibration with combined climatic conditioning, classical and pyroshock, drop, temperature, humidity, thermal shock, altitude to 100,000 ft, IP dust and water, salt spray, sand and dust, rain and fluid susceptibility. Main standards are IEC 60068, MIL-STD-810, RTCA DO-160, DEF STAN 00-35, ISO 16750 and IEC 60529. The lab is UKAS-accredited to ISO 17025, lab number 9373, and is an ISTA Certified Laboratory. Capacity includes a 70 kN shaker. It serves space, aerospace, defence, automotive, energy, medical and industrial customers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Rhymney Test Equipment (Testing House)
Rhymney, Caerphilly
New
Rhymney Test Equipment (Testing House) in Rhymney runs an environmental testing laboratory for climatic and corrosion work. Tests include dry heat to +180°C, cold to -70°C, temperature cycling, thermal shock, humidity, salt spray and transport simulation, for design and development, standards compliance, accelerated life testing and production monitoring. Main standards are IEC 60068, DEF STAN 00-35, MIL-STD-810, ASTM B117 and ISO 9227. The lab is UKAS-accredited to ISO 17025, lab number 22985, and holds ISO 9001. Its largest climatic chamber measures 1.5 m x 2.4 m x 1.5 m. The company also offers chamber calibration, chamber hire and chamber sales.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
TÜV SÜD Fareham
Fareham, Hampshire
New
TÜV SÜD Fareham runs climatic and vibration environmental test facilities at its Hampshire headquarters alongside EMC, radio and electrical safety labs. Its tests cover high and low temperature, damp heat, thermal shock, altitude, rapid decompression, salt corrosion, icing, fluid contamination, water ingress to IPX8, sine and random vibration, shock, drop and transit testing, to standards including IEC 60068, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 0141. Capacity includes climatic chambers up to 5.0 m x 6.0 m x 4.0 m and shakers up to 151 kN. Product groups served include aerospace, defence, rail, marine, satellites and medical devices.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Transport and packaging testing labs in the UK check that a product and its packaging survive shipping and handling. The tests recreate what happens in transit: vibration from road, rail, air or sea transport, drops and impacts, and compression from stacking. They are used to design packaging, to prove that a product ships safely and to meet carrier and retailer requirements.
Start with the test procedure. ISTA publishes test procedures for parcel and freight shipping, with series from basic tests to simulations of specific delivery networks, and ASTM D4169 covers performance testing of shipping containers and systems. Ask which procedure and level your carrier or customer requires, the sizes and weights of the packages and whether the lab can test the full shipping unit. Agree how damage is judged and reported.
7 of the 45 UK labs listed here offer transport simulation or package drop and compression testing. Filter by test and standard, and check the lab's UKAS scope if you need an accredited report.
ISTA publishes standard procedures for testing packaged products for shipping, including drop, vibration and compression tests, with different series for parcel delivery and freight. A retailer or carrier may require a specific procedure and level.
What is ASTM D4169?
A standard practice for performance testing of shipping containers and systems. It lets you choose a sequence of hazards, such as handling, vibration and compression, and levels that represent the distribution you expect.
Do I need to test the product or the package?
Both together. The test checks that the packaged product survives, so the lab needs the product, its packaging and enough samples. If you are developing packaging, say so, and the lab can test several designs against the same procedure.
What does the lab report?
Usually the procedure and level, the test sequence, the condition of the package and product after each stage and photographs. Agree the pass criteria before testing starts.