"Climatic testing" covers several different tests. A product can pass a steady hot soak and still crack in a thermal shock test, or pass both and then fail after a week of condensing humidity. Each test simulates a different part of the product's life, so the useful question is not "which test is hardest?" but "which conditions will this product actually meet?" This guide explains what the main climatic tests do, the IEC 60068 parts that define them, and how to choose between them.
Cold and dry heat: can it work and survive at the extremes?
The simplest climatic tests hold the product at a fixed temperature. IEC 60068-2-1 (Test A: Cold) and IEC 60068-2-2 (Test B: Dry heat) set out how to expose a product to low and high temperatures. Labs run them with the product switched off to represent storage and transport, or powered and working to represent use. Both cover products that give off heat in use, which matters for electronics: a powered assembly runs hotter inside than the chamber air.
Use them to answer two questions: will the product start and work at its rated temperature limits, and will it survive storage at the limits it may meet in a warehouse, a vehicle or a cargo hold?
Thermal cycling: slow, repeated temperature change
IEC 60068-2-14 (Test N: Change of temperature) covers tests where the temperature changes. Test Nb changes the temperature at a specified rate in a single chamber, repeated over a number of cycles. This is what most people mean by thermal cycling.
Repeated heating and cooling makes materials expand and contract at different rates. Over many cycles that strain can show up as fatigue in solder joints, cracked component bodies, lifting coatings and loosening fixings. Thermal cycling suits products that go through regular temperature swings in use: equipment in vehicles, outdoor enclosures that heat by day and cool by night, or electronics that warm up and cool down every time they are switched on and off.
Thermal shock: fast transfer between extremes
The same standard covers rapid change. Test Na is a rapid change of temperature, often run by moving the product between a hot chamber and a cold chamber, and Test Nc is a rapid change using two fluid baths. The point is speed: the outside of the product changes temperature much faster than the inside, so the stress is concentrated at joints, seals, potting and interfaces between different materials.
Thermal shock suits products that really do see sudden changes, such as equipment carried from a heated building into freezing air, or parts splashed with cold water when hot. It is a harsher test and can produce failures a product would never see in service. If the product only meets slow changes, a thermal cycling test is usually the closer match.
Damp heat, steady state: moisture getting in
IEC 60068-2-78 (Test Cab: Damp heat, steady state) holds the product at high humidity and a constant temperature, without condensation, for a set period. It looks at the effect of moisture absorbed into and diffusing through the product: swelling or weakening of plastics, changes to insulation resistance, and corrosion that needs moisture to start. It suits products stored or used for long periods in warm, humid air.
Damp heat, cyclic: condensation
IEC 60068-2-30 (Test Db: Damp heat, cyclic (12 h + 12 h cycle)) combines high humidity with temperature cycling, which in general produces condensation on the surface of the product. This is the test for equipment that sees dew or condensation in real life, such as outdoor, marine-adjacent or unheated installations, and for checking that seals and conformal coatings keep water off the electronics inside.
Match the test to how the product is used
Start with the product's life, not with the standard. Write down where it is stored, how it is shipped, where it is installed and how it is used day to day. Then pick tests that reproduce those conditions:
- Stored or shipped through cold or hot places: cold and dry heat storage tests, product switched off
- Must work at its rated limits: cold and dry heat operating tests, product powered and monitored
- Regular, gradual temperature swings in use: thermal cycling (Test Nb)
- Sudden changes, or interfaces between very different materials: thermal shock (Test Na or Nc)
- Long periods in warm, humid air: steady-state damp heat (Test Cab)
- Condensation, dew or breathing enclosures: cyclic damp heat (Test Db)
Many programmes need more than one. A common pattern is operating and storage temperature tests to prove the rated limits, plus either thermal cycling or thermal shock for durability, plus a damp heat test chosen by whether condensation is expected. If your customer or sector names a standard, follow it: defence, aerospace and automotive programmes often call up their own methods, and our guide to DEF STAN 00-35, MIL-STD-810 and DO-160 explains how those differ. If you want to find the design's limits rather than pass a specification, our guide to HALT, HASS and stress screening covers that. Temperature and vibration are often combined, and our separate guide to vibration testing covers that side.
Questions to ask a lab
- Which IEC 60068 part, test and severity will you run, and is it within your accredited scope?
- What are the chamber's temperature range, humidity range and rate of change?
- For thermal shock, how long does the transfer between hot and cold take?
- Can you power and monitor the product during the test, and how are faults recorded?
Quick-reference checklist
- List where the product is stored, shipped, installed and used
- Choose cold and dry heat for limits, cycling or shock for durability, damp heat for moisture
- Pick steady-state damp heat for absorption, cyclic damp heat for condensation
- State the standard, test, severity and number of cycles in the enquiry
- Say whether the product is powered and what counts as a failure
Where to go for more
The International Electrotechnical Commission publishes the IEC 60068 series of environmental testing standards, and UK adoptions are available from BSI. UKAS publishes lab accreditation schedules, so you can check a lab's accredited scope covers your test.
Find climatic test labs on ESS Directory
Browse UK labs offering climatic, temperature and humidity testing. Filter by test and standard, save the labs that fit to your shortlist, compare them side by side and send one enquiry to the whole shortlist at once. Our guide to choosing a UK environmental test lab covers the wider questions to ask.
For press enquiries about ESS Directory, contact ess@essdirectory.co.uk.
Listings related to this article

Environmental Test Services (ETS)
Reading, Berkshire
Environmental Test Services is an independent, owner-managed environmental test laboratory in Reading, Berkshire. It runs vibration, shock, temperature and humidity, altitude and decompression, salt spray and IP testing, including combined temperature and vibration, thermal shock, icing and drop tests. Work is carried out to DEF STAN 00-35, MIL-STD-810, RTCA DO-160 and the IEC 60068 series, with IP testing to IEC 60529. The laboratory is UKAS-accredited to ISO 17025, lab number 1909. Facilities include a walk-in climatic chamber of 1.8 m x 2.4 m x 2.4 m and electromagnetic vibrators of up to 28 kN. Tested product types include aerospace, marine, satellite, telecoms and motor vehicle equipment.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock
HORIBA MIRA Basildon
Basildon, Essex
HORIBA MIRA Basildon, at Quatro Park in Basildon, Essex, tests components and systems under vibration, climatic cycling, thermal shock, mechanical shock, corrosion and ingress protection. Facilities include 13 environmental chambers from 180 to 2,000 litres, two 36,000-litre walk-in chambers, electromagnetic vibrators and large battery shakers, including an IMV K350 with 900 kN shock thrust. Work is carried out to IEC 60068, MIL-STD-810, DEF STAN 00-35 and RTCA DO-160, including electric vehicle battery packs and modules. The site is UKAS-accredited to ISO 17025, lab number 2654, and serves the automotive, defence and aerospace sectors.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock
Leonardo Environmental Test Lab (Edinburgh)
Edinburgh
Leonardo Environmental Test Lab in Edinburgh carries out climatic, dynamic and EMC testing at Leonardo UK's Crewe Toll site. Climatic tests cover high and low temperature from -60°C to +180°C, damp heat, thermal shock, altitude to 100,000 ft, rapid decompression, solar radiation, salt mist, immersion, drip and fluid contamination. Dynamic tests include sine and random vibration on shakers up to 13,000 lbf, combined temperature and vibration, shock, bump and drop. Standards include IEC 60068, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 0461, with climatic chambers up to 4 m x 1.5 m x 1.8 m.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock

PARC (Product Assessment & Reliability Centre)
Bideford, Devon
PARC (Product Assessment & Reliability Centre) in Bideford, Devon, is an environmental test laboratory and part of the Apave group through Sopemea. It runs high and low temperature, damp heat, thermal shock, altitude, icing, rain, salt spray, IP, vibration, shock, bump and drop tests to IEC 60068, MIL-STD-810, DEF STAN 00-035, RTCA DO-160, ISO 16750 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 2379. Capacity includes temperature chambers of up to 2.7 m x 2.7 m x 2.7 m and a vibration system with 89 kN random force. It serves aerospace, defence, automotive, rail, marine, oil and gas and telecoms customers.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock
TÜV SÜD Fareham
Fareham, Hampshire
TÜV SÜD Fareham runs climatic and vibration environmental test facilities at its Hampshire headquarters alongside EMC, radio and electrical safety labs. Its tests cover high and low temperature, damp heat, thermal shock, altitude, rapid decompression, salt corrosion, icing, fluid contamination, water ingress to IPX8, sine and random vibration, shock, drop and transit testing, to standards including IEC 60068, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 0141. Capacity includes climatic chambers up to 5.0 m x 6.0 m x 4.0 m and shakers up to 151 kN. Product groups served include aerospace, defence, rail, marine, satellites and medical devices.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock
UTAC UK Millbrook
Bedford, Bedfordshire
UTAC UK Millbrook, near Bedford, is a vehicle proving ground with component environmental, battery, crash and fire test laboratories. Its accredited environmental scope covers high and low temperature from -60°C to +110°C, solar radiation thermal effects, steady and cyclic humidity, and sine and random vibration, to IEC 60068 and DEF STAN 00-35, plus thermal shock, cycling and mechanical shock tests on vehicle battery packs to UN ECE R100. The lab is UKAS-accredited to ISO 17025, lab number 2498. Capacity includes a climatic chamber working area of 11 m x 5 m x 4 m and a 24 kN shaker. It serves automotive, aerospace, rail and defence customers.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock