Alphatech in Haverhill runs an independent UKAS-accredited environmental test lab alongside its chamber sales, hire and service business. The lab covers high and low temperature, damp heat, thermal shock, sine and random vibration, shock, bump, drop and topple, HALT and HASS, IP dust and water ingress up to IPX9K, neutral salt spray and altitude. Standards include BS EN 60068, IEC 60529, ISO 20653, ISO 16750, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. It is accredited to ISO 17025, lab number 2645, with shakers of up to 40 kN. Customers can stay on site during testing.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Reltech
Dursley, Gloucestershire
New
Reltech in Dursley, Gloucestershire, is an independent test laboratory for semiconductor devices and electronic components. It runs high and low temperature operating life and storage tests, temperature and power cycling, temperature-humidity bias (THB) and HAST moisture testing, burn-in screening, ESD and latch-up testing and failure analysis. Work follows JEDEC JESD22 methods and AEC-Q100 qualification requirements. The laboratory is UKAS-accredited to ISO 17025, lab number 2806, and also designs and builds its own HTOL systems. It serves automotive, aerospace and defence, space, medical and telecommunications customers, as well as AI and power device makers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Production Stress Screening
RG
Rivencore Global Solutions
Poole, Dorset
New
Rivencore Global Solutions in Poole offers environmental testing from its laboratory on the south coast. Tests include dry heat, low temperature, change of temperature and humidity in a 1,500-litre climatic chamber covering -70°C to +180°C, IP dust and water ingress from IP5X and IPX1 to IPX8, drop testing up to 15 kg, mechanical strength testing and HALT with combined random vibration and temperature stress. Main standards are IEC 60068, IEC 60529, MIL-STD-810, BS EN 60945 and IEC 62368-1. The laboratory is UKAS-accredited to ISO 17025, lab number 28772.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Bump and Drop
HALT, HASS and stress screening labs in the UK run tests that go beyond a pass or fail qualification. HALT, the highly accelerated life test, applies stepped stresses such as rapid temperature change and vibration, well beyond the specification, to find a design's limits and weak points while it can still be changed. HASS, the highly accelerated stress screen, and conventional environmental stress screening are production tests that look for manufacturing defects in each unit or a sample.
These tests need specialist equipment, usually a chamber that combines fast thermal change with multi-axis vibration, and not every environmental lab has it. HALT is listed by 2 of the 45 UK labs here, HASS by 1 and production stress screening by 1 so it is worth asking early whether the lab has the chamber and a free slot. Ask who sets the test steps and how a screening profile is derived and proved on good units before it is used in production.
HALT is a development test that pushes a few samples beyond their specification to find operating and destruct limits, so weaknesses can be designed out. HASS is a production screen, with levels derived from the HALT results, that finds manufacturing defects in units that are then shipped if they pass. HALT finds design problems and HASS finds production problems.
Is HALT a pass or fail test?
No. HALT is exploratory, and its result is a set of limits and failure modes, not a pass or fail. Qualification tests to a standard such as IEC 60068 or MIL-STD-810 are pass or fail against a specification, and HALT does not replace them.
When should I run HALT?
During development, on a small number of samples, while the design can still be changed. Running it late finds the same problems at higher cost. Plan the products, the monitoring and the pass criteria for operation with the lab beforehand.
What do I need to ask a HALT lab?
Whether the chamber is a dedicated HALT and HASS chamber, its temperature range and rate of change, the vibration axes and levels, how the product is powered and monitored, who designs the fixture, and what the report contains. Ask also how soon a slot is available.