Particle Technology in Hatton, Derbyshire, runs sand and dust and ingress protection testing alongside particle and filter analysis services. Its UKAS ISO 17025 scope, lab number 4109, covers turbulent dust and driving sand and dust to DEF STAN 00-035, MIL-STD-810 Method 510 and RTCA DO-160 Section 12, and IP dust and water testing to IEC 60529 and ISO 20653. Facilities include a 12.5 x 4 x 6 m blowing and turbulent dust chamber with a 4 m high access door, and a second 4 x 4 x 3 m dust chamber. It works with defence, aerospace, automotive, medical and telecommunications customers.
Blowing Sand and Dust
IP Dust (IP5X/IP6X)
IP Water (IPX1 to IPX9K)
SGS Buxton
Buxton, Derbyshire
FeaturedNew
SGS Buxton is a product safety laboratory in Buxton, Derbyshire, that incorporates Baseefa and tests equipment for use in potentially explosive atmospheres. It carries out ingress protection testing to IEC 60529 for dust and water, covering IP5X and IP6X dust and IPX1 to IPX8 water, with immersion to 100 metres. Environmental exposure tests include heat endurance at 95°C and 90% RH, dry heat to 250°C and cold endurance to -75°C under IEC 60079-0. The laboratory is UKAS-accredited to ISO 17025, lab number 2593. It serves automotive, industrial, medical device, radio equipment, electricity meter and consumer goods customers.
IP Dust (IP5X/IP6X)
IP Water (IPX1 to IPX9K)
Temperature (Hot/Cold)
Humidity/Damp Heat
Alphatech
Haverhill, Suffolk
New
Alphatech in Haverhill runs an independent UKAS-accredited environmental test lab alongside its chamber sales, hire and service business. The lab covers high and low temperature, damp heat, thermal shock, sine and random vibration, shock, bump, drop and topple, HALT and HASS, IP dust and water ingress up to IPX9K, neutral salt spray and altitude. Standards include BS EN 60068, IEC 60529, ISO 20653, ISO 16750, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. It is accredited to ISO 17025, lab number 2645, with shakers of up to 40 kN. Customers can stay on site during testing.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Cranage EMC & Safety
Market Drayton, Shropshire
New
Cranage EMC & Safety in Market Drayton, Shropshire, runs environmental tests alongside EMC and product safety work. Its climatic chambers cover temperature, humidity and damp heat, temperature cycling, solar radiation and salt spray. Mechanical tests include random and swept sine vibration from 5 Hz to 2 kHz and shock up to 500 m/s². Ingress protection testing covers dust and water from IP1X to IPX9K, with a 50 m² indoor IPX9K area. Standards include IEC 60068 and IEC 60529. The lab is UKAS-accredited to ISO 17025, lab number 1833, and serves medical, rail and industrial equipment makers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Solar Radiation
Element Warwick
Warwick, Warwickshire
New
Element Warwick, in Warwick, is an environmental test laboratory running climatic, dynamic and ingress protection tests. Climatic work covers high and low temperature, humidity, thermal shock, altitude to 35 mbar, driving sand and dust, driving rain, icing and salt corrosion. Dynamic work covers sine and random vibration on a shaker with 160 kN peak thrust, vibration at high and low temperature, classical shock, bump, drop and topple, and acceleration. IP testing covers IP5X to IPX8. Standards include IEC 60068, MIL-STD-810, DEF STAN 00-35, IEC 61373 and IEC 60529. It is UKAS-accredited to ISO 17025, lab number 31737, and serves aerospace, defence, energy and industrial sectors.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Shock
Combined Climatic and Vibration
Environmental Test Services (ETS)
Reading, Berkshire
New
Environmental Test Services is an independent, owner-managed environmental test laboratory in Reading, Berkshire. It runs vibration, shock, temperature and humidity, altitude and decompression, salt spray and IP testing, including combined temperature and vibration, thermal shock, icing and drop tests. Work is carried out to DEF STAN 00-35, MIL-STD-810, RTCA DO-160 and the IEC 60068 series, with IP testing to IEC 60529. The laboratory is UKAS-accredited to ISO 17025, lab number 1909. Facilities include a walk-in climatic chamber of 1.8 m x 2.4 m x 2.4 m and electromagnetic vibrators of up to 28 kN. Tested product types include aerospace, marine, satellite, telecoms and motor vehicle equipment.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Eurofins E&E CML
Ellesmere Port, Cheshire
New
Eurofins E&E CML in Ellesmere Port, Cheshire, is a hazardous-area (Ex) certification body and test laboratory, now part of UL Solutions. It offers ingress protection testing to IEC 60529, either within a certification project or as stand-alone testing, covering dust (IP5X and IP6X, enclosures up to about 2.2 m x 1.3 m) and water from IPX3 to IPX9K, with immersion to 100 m. Environmental tests cover temperature from -60°C to 200°C, humidity up to 95°C and 90% RH, and UV exposure to ISO 4892. The laboratory is UKAS-accredited to ISO 17025, lab number 8175, and is an IECEx test laboratory (ExTL).
Temperature (Hot/Cold)
Humidity/Damp Heat
IP Dust (IP5X/IP6X)
IP Water (IPX1 to IPX9K)
Eurofins E&E UK London
London, Greater London
New
Eurofins E&E UK London Laboratory in London is an electrical safety test laboratory, now part of UL Solutions. Alongside safety testing of household appliances, luminaires, wiring accessories and IT equipment, its UKAS scope includes ingress protection testing to IEC 60529, covering dust (IP5X and IP6X, for objects up to 1800 x 570 x 570 mm) and water from IPX1 to IPX8, with immersion to 1 m. It also holds UKAS scope for IK impact protection testing to IEC 62262. The laboratory is UKAS-accredited to ISO 17025, lab number 0225, for testing at its Western Road site.
IP Dust (IP5X/IP6X)
IP Water (IPX1 to IPX9K)
Ex Veritas
Wrexham
New
Ex Veritas is a hazardous-area certification body with test laboratories in Wrexham, Wales. Its laboratory offers ingress protection testing to EN 60529, covering dust-protected (IP5X) and dust-tight (IP6X) categories and water ingress from IPX3 to IPX8, plus NEMA 4 testing for North American approval. Environmental and safety facilities include four humidity and thermal conditioning chambers, thermal cycling and thermal shock testing, and drop tests. The Wrexham laboratory is UKAS-accredited to ISO 17025, lab number 8613, and is an IECEx test laboratory. Testing supports UKCA, ATEX, IECEx and North American approvals.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
IL
Intertek Leatherhead
Leatherhead, Surrey
New
Intertek Leatherhead, in Leatherhead, Surrey, runs climatic, vibration, shock and ingress testing alongside EMC, safety and medical testing at one site. Climatic work covers dry heat to +180 C, cold to -75 C, thermal cycling, and cyclic and steady-state damp heat from 10% to 98% rh, to IEC 60068 and MIL-STD-810. Mechanical tests include sine vibration from 2 to 5,000 Hz and half-sine shock up to 5,000 g. Dust and water ingress tests run to IEC 60529, covering IP5X and IP6X dust and IPX1 to IPX8 water. The lab is UKAS-accredited to ISO 17025, lab number 0029, and serves electronics, medical, automotive, building, industrial and energy customers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Sine Vibration
Kiwa Electrical Compliance
Blackwood, Caerphilly
New
Kiwa Electrical Compliance in Blackwood, South Wales, is an EMC, radio and electrical safety test laboratory that also provides ingress protection testing. IP testing follows IEC 60529 and EN 60529, covering probe tests from IP1X to IP4X, dust tests to IP5X and IP6X in a talc powder chamber, and water tests from IPX1 to IPX8 using dripping, spray, jet and immersion fixtures. Pre-compliance reviews and targeted trials are available before formal testing. The laboratory is UKAS-accredited to ISO 17025 for EMC and electrical safety testing, lab number 2667.
IP Dust (IP5X/IP6X)
IP Water (IPX1 to IPX9K)
Leonardo Environmental Test Lab (Edinburgh)
Edinburgh
New
Leonardo Environmental Test Lab in Edinburgh carries out climatic, dynamic and EMC testing at Leonardo UK's Crewe Toll site. Climatic tests cover high and low temperature from -60°C to +180°C, damp heat, thermal shock, altitude to 100,000 ft, rapid decompression, solar radiation, salt mist, immersion, drip and fluid contamination. Dynamic tests include sine and random vibration on shakers up to 13,000 lbf, combined temperature and vibration, shock, bump and drop. Standards include IEC 60068, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 0461, with climatic chambers up to 4 m x 1.5 m x 1.8 m.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
LIA Laboratory
Telford, Shropshire
New
LIA Laboratory in Telford is an independent, UKAS-accredited test laboratory for lighting and electrical products. Alongside luminaire safety, photometry, flammability and control gear testing, it carries out ingress protection testing to EN 60529, covering dust-protected tests and water tests from IPX3 to IPX8, including submersion to a maximum depth of 100 metres. IP testing of luminaires is also carried out to EN IEC 60598-1, together with IK impact testing. The laboratory is UKAS-accredited to ISO 17025, lab number 1286, and is a UK National Certification Body under the IECEE CB scheme.
IP Dust (IP5X/IP6X)
IP Water (IPX1 to IPX9K)
MS Testing
Newton Aycliffe, Durham
New
MS Testing in Newton Aycliffe, County Durham, is a test laboratory for environmental, EMC and marine type approval work. Its environmental testing covers high and low temperature, damp heat, thermal shock, salt mist, sine and random vibration, half-sine shock, static and dynamic inclination, and dust and water ingress from IP1X to IPX8. Tests are run to IEC 60068, IEC 60529, IEC 60945 and IACS E10. The lab is UKAS-accredited to ISO 17025, lab number 4413, and its largest climatic chamber measures 1.6 m x 1.9 m x 1.6 m. Its main sector is marine equipment, and its salt spray testing also serves automotive components.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
PARC (Product Assessment & Reliability Centre)
Bideford, Devon
New
PARC (Product Assessment & Reliability Centre) in Bideford, Devon, is an environmental test laboratory and part of the Apave group through Sopemea. It runs high and low temperature, damp heat, thermal shock, altitude, icing, rain, salt spray, IP, vibration, shock, bump and drop tests to IEC 60068, MIL-STD-810, DEF STAN 00-035, RTCA DO-160, ISO 16750 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 2379. Capacity includes temperature chambers of up to 2.7 m x 2.7 m x 2.7 m and a vibration system with 89 kN random force. It serves aerospace, defence, automotive, rail, marine, oil and gas and telecoms customers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
Resonate Testing
Newry, County Down
New
Resonate Testing in Newry provides vibration, shock, climatic, ingress protection, battery and fire testing from a single facility. Tests include sine and random vibration with combined climatic conditioning, classical and pyroshock, drop, temperature, humidity, thermal shock, altitude to 100,000 ft, IP dust and water, salt spray, sand and dust, rain and fluid susceptibility. Main standards are IEC 60068, MIL-STD-810, RTCA DO-160, DEF STAN 00-35, ISO 16750 and IEC 60529. The lab is UKAS-accredited to ISO 17025, lab number 9373, and is an ISTA Certified Laboratory. Capacity includes a 70 kN shaker. It serves space, aerospace, defence, automotive, energy, medical and industrial customers.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
RG
Rivencore Global Solutions
Poole, Dorset
New
Rivencore Global Solutions in Poole offers environmental testing from its laboratory on the south coast. Tests include dry heat, low temperature, change of temperature and humidity in a 1,500-litre climatic chamber covering -70°C to +180°C, IP dust and water ingress from IP5X and IPX1 to IPX8, drop testing up to 15 kg, mechanical strength testing and HALT with combined random vibration and temperature stress. Main standards are IEC 60068, IEC 60529, MIL-STD-810, BS EN 60945 and IEC 62368-1. The laboratory is UKAS-accredited to ISO 17025, lab number 28772.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Bump and Drop
TÜV SÜD Fareham
Fareham, Hampshire
New
TÜV SÜD Fareham runs climatic and vibration environmental test facilities at its Hampshire headquarters alongside EMC, radio and electrical safety labs. Its tests cover high and low temperature, damp heat, thermal shock, altitude, rapid decompression, salt corrosion, icing, fluid contamination, water ingress to IPX8, sine and random vibration, shock, drop and transit testing, to standards including IEC 60068, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 0141. Capacity includes climatic chambers up to 5.0 m x 6.0 m x 4.0 m and shakers up to 151 kN. Product groups served include aerospace, defence, rail, marine, satellites and medical devices.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
ZF Automotive UK Test & Validation
Solihull, West Midlands
New
ZF Automotive UK Test & Validation in Solihull offers EMC, environmental and materials testing for automotive and other industry components. Its environmental scope covers dry heat, low temperature, humidity, thermal cycling and thermal shock, salt mist, IP dust and water to IPX9K, icing, fluid contamination, low pressure, and sine, random, shock, bump and drop testing, with combined temperature and vibration. Standards include IEC 60068, MIL-STD-810, DEF STAN 00-35, RTCA DO-160, ISO 16750 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 0332. Capacity includes 2,500-litre climatic chambers and a 66 kN shaker. It serves automotive, aerospace and rail.
Temperature (Hot/Cold)
Humidity/Damp Heat
Thermal Cycling
Thermal Shock
IP testing labs in the UK test whether an enclosure keeps out dust and water. The IP code, defined in IEC 60529, has two digits: the first states protection against solid objects and dust, from IP5X (dust-protected) to IP6X (dust-tight), and the second states protection against water, from dripping and sprays to jets, temporary immersion and continuous immersion. For road vehicles, ISO 20653 adds the high-pressure, high-temperature jet test known as IPX9K.
Start with the rating you have claimed or been asked to meet, for example IP65, IP67 or IP69K, and ask the lab which tests that involves. Water tests range from drip and spray rigs to jets, immersion tanks and pressurised chambers, and dust tests use a dust chamber. Check the size of the product against the rig, and whether the product must be powered or monitored for leaks.
19 of the 45 UK labs listed here offer IP testing, and 19 state IEC 60529. If you need an accredited test report, check that the test is in the lab's UKAS scope. Use our guide to choosing a UK environmental test lab for the questions to ask, and our guide to IP rating testing for what IP67 means and how the test works.
The first digit is protection against solid objects and dust, and the second is protection against water. IP67 means dust-tight and protected against temporary immersion. IP68 means dust-tight and protected against continuous immersion under conditions the manufacturer states. The standard is IEC 60529.
What is IPX9K?
IPX9K is a rating for protection against high-pressure, high-temperature water jets, used mainly for road vehicles and defined in ISO 20653. It is a harder test than the water jet tests in IEC 60529, so check which one your customer asks for.
Does a lab need to be accredited to issue an IP test report?
Not always, but some customers and regulators ask for accredited reports. UKAS accreditation covers a defined scope, so if you need it, say so in your enquiry and check that IP testing is on the lab's schedule.
How many samples do I need to send?
It depends on the specification and the lab, and tests can be destructive for the seals. Ask the lab how many samples the test needs, and whether it needs spare enclosures to set up the rig.