IP Rating Testing: What IP67 Means and How the Test Works
Buyer Guides · 9 November 2026

"IP67" appears on data sheets for everything from sensors to handheld instruments, but the two digits describe two separate tests, run under defined conditions. Knowing what each digit means, and how the test behind it works, helps you set the right requirement and get a useful quote from a lab. This guide covers the IP code, the common tests and the questions to ask before you book.
Where the IP code comes from
The IP code is defined in IEC 60529, Degrees of protection provided by enclosures, published in the UK as BS EN 60529. It classifies how well an enclosure for electrical equipment keeps out solid objects, including dust, and water, and how well it stops people reaching hazardous parts. The code is "IP" followed by two digits. An "X" in place of a digit means that property has not been specified or tested, so IPX7 says nothing about dust.
The first digit: solids and dust
| Digit | Protection against |
|---|---|
| 0 | Not protected |
| 1 | Solid objects of 50 mm and larger, such as the back of a hand |
| 2 | Solid objects of 12.5 mm and larger, such as fingers |
| 3 | Solid objects of 2.5 mm and larger, such as tools |
| 4 | Solid objects of 1.0 mm and larger, such as wires |
| 5 | Dust-protected: some dust may enter, but not enough to stop safe operation |
| 6 | Dust-tight: no dust enters |
Digits 1 to 4 are checked with test probes of the stated size. Digits 5 and 6 are tested in a dust chamber.
The second digit: water
| Digit | Protection against |
|---|---|
| 0 | Not protected |
| 1 | Vertically dripping water |
| 2 | Dripping water with the enclosure tilted up to 15° |
| 3 | Spraying water |
| 4 | Splashing water from any direction |
| 5 | Water jets |
| 6 | Powerful water jets |
| 7 | Temporary immersion |
| 8 | Continuous immersion, under conditions agreed with the manufacturer |
| 9 | High-pressure, high-temperature water jets |
Up to 6, a higher water digit covers the lower ones. Immersion is different: IPX7 does not automatically cover IPX5 or IPX6, because jets and immersion are different tests. A product that needs both carries a dual rating, for example IP66/IP67.
How the common tests work
Dust (IP5X and IP6X). The product sits in a sealed chamber where talcum powder is kept in suspension by circulating air. For enclosures that "breathe" as they warm and cool, a vacuum pump lowers the pressure inside the enclosure, by no more than 2 kPa, to draw in a set volume of dusty air: 80 times the enclosure volume. The test lasts 2 hours if that volume is drawn quickly enough, and up to 8 hours if not. Afterwards the inside is inspected: IP6X allows no dust inside.
Drips and spray (IPX1 to IPX4). Drip tests use a drip box above the product, with the product on a turntable or tilted. Spray and splash tests use an oscillating tube or a hand-held spray nozzle, over a wider arc for IPX4 than for IPX3.
Jets (IPX5 and IPX6). A hose nozzle is aimed at the enclosure from 2.5 to 3 m, covering every practical direction. IPX5 uses a 6.3 mm nozzle at 12.5 litres per minute. IPX6 uses a 12.5 mm nozzle at 100 litres per minute. Both run for 1 minute per square metre of surface, with a minimum of 3 minutes.
Immersion (IPX7 and IPX8). For IPX7, the enclosure is submerged so that its lowest point is 1 m below the surface, or its highest point 0.15 m below for taller items, for 30 minutes. IPX8 has no single fixed test: the depth and duration are agreed between the manufacturer and the user and must be more severe than IPX7. Always ask what "IP68" means for a given product.
After a water test the enclosure is opened and inspected. The product standard or your own specification usually decides how much water, if any, is acceptable and whether the product must work during and after the test.
IP69K and ISO 20653
ISO 20653 applies the IP code to electrical equipment on road vehicles. It follows IEC 60529 but adds "K" codes for road-vehicle conditions, such as IPX9K. The IP69K test sprays the product with hot water, at around 80 °C, at high pressure from close range and at several angles while it turns on a turntable. It is common for vehicle equipment that is pressure-washed and for food and process equipment cleaned with hot, high-pressure water. IEC 60529 also has its own IPX9 test, so check which standard your customer means.
What to ask an IP test lab
- Which edition of IEC 60529, or which other standard such as ISO 20653, will you test to?
- Is the test on your UKAS schedule of accreditation?
- For dust: will the enclosure be tested under vacuum, and how will you connect the vacuum line?
- For IPX8: what depth and duration do you propose, and how will they be recorded?
- Will the product be powered and monitored during the test?
- What are the pass criteria, and who sets them: the standard, the product standard or us?
- Can you test cable glands, connectors and seals as fitted, in the final orientation?
- What does the report contain: photographs, conditions, inspection findings?
Quick checklist
- Write the full code you need, digit by digit, and the standard it refers to
- Specify both jet and immersion ratings if the product will see both
- Agree IPX8 depth and duration in writing
- Test production-representative samples with real seals, glands and connectors
- State the pass criteria before the test, not after
Our guides on choosing a UK environmental test lab and on which environmental test standard you need cover accreditation, capacity and standards in more detail.
Where to go for more
The IEC publishes IEC 60529, and BSI publishes the UK edition, BS EN 60529. UKAS publishes each accredited lab's schedule.
Find IP test labs on ESS Directory
Compare UK labs for IP and ingress testing, along with sand, dust and mud testing and rain, ice and fluid testing. Save the labs that fit to your shortlist and send one enquiry to the whole shortlist at once.
For press enquiries about ESS Directory, contact ess@essdirectory.co.uk.
Listings related to this article

Alphatech
Haverhill, Suffolk
Alphatech in Haverhill runs an independent UKAS-accredited environmental test lab alongside its chamber sales, hire and service business. The lab covers high and low temperature, damp heat, thermal shock, sine and random vibration, shock, bump, drop and topple, HALT and HASS, IP dust and water ingress up to IPX9K, neutral salt spray and altitude. Standards include BS EN 60068, IEC 60529, ISO 20653, ISO 16750, MIL-STD-810, DEF STAN 00-35, RTCA DO-160 and EN 61373. It is accredited to ISO 17025, lab number 2645, with shakers of up to 40 kN. Customers can stay on site during testing.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock

PARC (Product Assessment & Reliability Centre)
Bideford, Devon
PARC (Product Assessment & Reliability Centre) in Bideford, Devon, is an environmental test laboratory and part of the Apave group through Sopemea. It runs high and low temperature, damp heat, thermal shock, altitude, icing, rain, salt spray, IP, vibration, shock, bump and drop tests to IEC 60068, MIL-STD-810, DEF STAN 00-035, RTCA DO-160, ISO 16750 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 2379. Capacity includes temperature chambers of up to 2.7 m x 2.7 m x 2.7 m and a vibration system with 89 kN random force. It serves aerospace, defence, automotive, rail, marine, oil and gas and telecoms customers.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock

Particle Technology
Hatton, Derbyshire
Particle Technology in Hatton, Derbyshire, runs sand and dust and ingress protection testing alongside particle and filter analysis services. Its UKAS ISO 17025 scope, lab number 4109, covers turbulent dust and driving sand and dust to DEF STAN 00-035, MIL-STD-810 Method 510 and RTCA DO-160 Section 12, and IP dust and water testing to IEC 60529 and ISO 20653. Facilities include a 12.5 x 4 x 6 m blowing and turbulent dust chamber with a 4 m high access door, and a second 4 x 4 x 3 m dust chamber. It works with defence, aerospace, automotive, medical and telecommunications customers.
- Blowing Sand and Dust
- IP Dust (IP5X/IP6X)
- IP Water (IPX1 to IPX9K)
Resonate Testing
Newry, County Down
Resonate Testing in Newry provides vibration, shock, climatic, ingress protection, battery and fire testing from a single facility. Tests include sine and random vibration with combined climatic conditioning, classical and pyroshock, drop, temperature, humidity, thermal shock, altitude to 100,000 ft, IP dust and water, salt spray, sand and dust, rain and fluid susceptibility. Main standards are IEC 60068, MIL-STD-810, RTCA DO-160, DEF STAN 00-35, ISO 16750 and IEC 60529. The lab is UKAS-accredited to ISO 17025, lab number 9373, and is an ISTA Certified Laboratory. Capacity includes a 70 kN shaker. It serves space, aerospace, defence, automotive, energy, medical and industrial customers.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock
ZF Automotive UK Test & Validation
Solihull, West Midlands
ZF Automotive UK Test & Validation in Solihull offers EMC, environmental and materials testing for automotive and other industry components. Its environmental scope covers dry heat, low temperature, humidity, thermal cycling and thermal shock, salt mist, IP dust and water to IPX9K, icing, fluid contamination, low pressure, and sine, random, shock, bump and drop testing, with combined temperature and vibration. Standards include IEC 60068, MIL-STD-810, DEF STAN 00-35, RTCA DO-160, ISO 16750 and EN 61373. The lab is UKAS-accredited to ISO 17025, lab number 0332. Capacity includes 2,500-litre climatic chambers and a 66 kN shaker. It serves automotive, aerospace and rail.
- Temperature (Hot/Cold)
- Humidity/Damp Heat
- Thermal Cycling
- Thermal Shock